Split load single RCCB

Split load single RCCB

18th Ed. Consumer units: Tested to meet the requirements of 536.4.201 - Icc 16kA / 230v as per BSEN 61439-3 Annex ZB. Refer to the installation instructions. SPD Selection: Where SPDs are required please refer to 534 4 8 and the SPD Manufacturer's installation instructions. Installing Type 1 SPDs in a consumer unit is difficult - see cabling requirements covered in 534.4.8 Et 10. *Note : SPDs are passive devices and do not add to the heat rise in the enclosure i.e. they only take up space that has been assigned / tested with Doepke components in situ. Leave 0.5 module space between the SPD and adjacent components to prevent direct heat.
  • Adaptable and compact for renewable energy installations
  • Heat pump consumer units c/w HP Type B RCCB
  • Versions available including Type A, F and B
  • For other combinations please contact us
  • We recommend the use of good quality SPD devices e.g. DEHN
Order Doepke MCBs/RCBOs separately - Please refer to the web page links: MCBs 6kA - Rated for conditional short-circuit current < 16kA as per CU installation instructions RCBOs 10kA - Rated for conditional short -circuit current < 16kA as per CU installation instructions
REACH Declaration

Variant: Type A

Find a Distributor
Selection
Refer to Technical Data for additional information
Main Sw. RCCB 1 Type A Usable Ways Reference
100A 63A 30mA 6 DCM06SL/063
100A 63A 30mA 10 DCM10SL/063
100A 63A 30mA 14 DCM14SL/063